MEETING CURRENT APPROVED DOCUMENT E (2003) (ENGLAND & WALES) REQUIREMENTS
To achieve these requirements two options are available:
1. PRE-COMPLETION TESTING or
2. ROBUST DETAILS FOR WHICH NO PCT IS REQUIRED
For dwelling-houses, flats and rooms for residential
purposes, the site acoustic performance requirements are: |
|
Robust detail requirements, using laboratory testing
over specified structural floors, are: |
SEPARATING FLOORS
BETWEEN DWEllINGS |
AIRBORNE
(DnT,w + Ctr) |
IMAPACT
(L'nT,w) |
| New Build |
45 dB min |
62 dB max |
| Created by material change of use |
43 dB min |
64 dB max |
|
|
STRUCTURAL
FLOOR TYPE |
AIRBORNE
(Rw + Ctr) |
IMAPACT
(Lw) |
| Concrete (E-FC-1, 2, 7 E-FS-1) |
45 dB min |
62 dB max |
| Timber (E-FT-1, 2, 3) |
43 dB min |
64 dB max |
(labratory tests carried out by UKAS accredited BRE and SRL) |
| GLOSSARY: |
| Rw = IMPROVEMENT IN AIRBORNE SOUND |
DnT,w = AIRBORNE SOUND INSULATION BETWEEN TWO ROOMS |
| Lw = IMPROVEMENT IN IMPACT SOUND |
L'nT,w = IMPACT SOUND INSULATION OF FLOORS |
| Ctr = LOW FREQUENCY CORRECTION FACTOR |
|
|