TECHNICAL INSTALLATION GUIDE FOR ATTENU8 ACOUSTIC UNDERLAY 10 ON TIMBER FLOORS
-
Following removal of any debris, attenu8 Acoustic Underlay 10 is laid foam down directly onto the timber floor.
-
It is preferred but not essential that it is bonded to the floor using a conventional contact adhesive, prior to the top surface being laid.
-
The whole area is covered, with the sheets butted tightly together and the joints taped.
-
Shaping or trimming can be done with a standard trimming blade.
-
If carpets are to be placed on top, again these are preferably glued on, and a 13mm timber strip should be around the perimeter to accept the gripper rod.
-
If timber or laminate is placed on top, these should be isolated from the wall using a flanking strip.
-
For other areas such as stairs, attenu8 Acoustic Underlay 10 will need to be cut and glued in place allowing for the timber perimeter strip for the gripper rod.
|